6/7/2023 0 Comments Carte a gesturilor pdf free![]() NOTE: You can purchase “ad free” copies of our articles, videos, and sample code for $1 each here. ![]() Step 8) Moving over to FactoryTalk View Studio, right click on your application in the Project Explorer and select “OPC Data Server” from the “Add New Server” menu: Or become a “ Patron” for as little as $1 a month and receive at least $3 worth of articles/videos/sample code free each month! Find out more here. ![]() Step 13) Now to see the tags available in your emulated PLC, you may need to right click in the Tag Browser and “Refresh All Folders” as shown below: Step 12) Then select “Apply” and “Close”: Step 11) Now select “RSLinx OPC Server” from the list, and click on “OK”: Step 10) Then under “OPC Server Name” select “Browse”: In the below example “RSLinx Classic” was used: Step 9) In the properties window, give your OPC Server a name. Step 14) Once the folders refresh, you should see the available PLC addresses in your emulated PLC: NOTE: One setting that could cause your tags not to appear would be if RSLinx Enterprise had “Shortcuts” with the same names as RSLinx Classic “Topics.” For example, if we had an RSLinx Enterprise “Shortcut” named “EMU1100,” we may not be able to browse for tags from our RSLinx Classic “Topic” of the same name. NOTE: Using RSLinx Classic and RSEmulate to test your graphics and animations can be very helpful.